McWade Productions

  +27 11 316 2262         
  sales@mcwade.co.za

  • Home
  • Our Company
    • Company Profile
    • Copyright & Warranties
    • ISO & B-BBEE Certificates
      • ISO9001:2015 Certificate
      • B-BBEE Level 2 Certificate
    • Privacy Policy
    • PAIA Manual
  • Our Products
    • Substation Interconnection Clamps
    • Distribution & Transmission Line Hardware
    • Disconnectors / Isolators
    • Insulators
    • Izumi Compression and Other Tools
  • Technical Info
    • Definitions, Formulas & Equations
    • Technical Information on Key Products
    • Miscellaneous Items
  • Agencies & Brands
    • Agencies
      • Efacec
      • Izumi Products Company
      • Jindal’s
      • Nedal Aluminium
      • Prysmian Group
      • SGD La Granja
      • Zibo Taiguam Electrical Company
    • Our Product Brands
      • Linegear 2000
      • B. Karg Engineering
      • CCL Compression Fittings
      • Elbroc Electrical
    • Associate Companies
      • Idube Electrical
      • Trugrid Sales
  • Catalogues
    • McWade Full Catalogue
    • McWade Technical Catalogue
    • Izumi Complete Catalogue
    • Linegear 2000 Catalogue
    • Efacec Catalogue
    • Jindal’s Catalogue
    • Prysmian Catalogue
    • Idube Electrical Catalogue
  • Credit Application
    • Open an account with McWade
  • Contact Us
    • Address
    • Phone numbers
    • Contact Form
    • Map
    • Wish to open an Account?
You are here: Home > Technical Info

Technical Info

Technical-Information-1200-x-200

Technical information about our products is shown here.   CLICK on the BLUE HEADLINES to open and close the categories..

Definitions, Formulas and Equations
Click on any TITLE in BLUE TYPE for details
============================ DEFINITIONS, FORMULAS AND EQUATIONS==============================================
————————— DEFINITIONS ——————————————————
Definitions of terms used in our documents

DEFINITIONS OF TERMS

 
STATE OF THE ART – The most up-to-date method of manufacture, material and testing.

NO DIES REQUIRED – The tool has a 4 way indention. Nibs are always concentric, on fitting. No loose dies to lose or replace.

DOUBLE ACTING – These tools have a low and high pressure valve to enable the tool to close rapidly on low pressure and to exert high pressure at the nib face.

MATERIALS TO CRIMP – Aluminium, Copper or Bimetal fittings, manufactured to suit “Bimetal 4 E” system.

TYPES OF FITTINGS TO BE CRIMPED – Round, shaped, oblong and C connectors – Aluminium or Copper.

APPLICATION IN TOOL – The Bimetal 4 E system is designed with locating grooves down the length of the fitting to enable the operator to align the tool head.

YELLOW HOT – LINE HANDLES – These handles are made of fibre glass and tested to 40kV DC. The crimping head may also be insulated with rubber.

PRESSURE (OPERATING) – All tools operate at 10, 500 PSI or 700 bar. or 64 kPA. and can be checked by means of a pressure gauge.

OIL – All tolls use hydraulic oil high spin 32.

BY PASS CARTRIDGE – The method of setting the pressure is unique and carries a worldwide patent. Situated externally for easy access.

CARRY CASE – All tools are supplied in a steel carry case for extra protection and safe keeping.

Adobe PDF

Download this page in PDF
————————— FORMULAS AND EQUATIONS ——————————————————
Formulas and Equations

FORMULAS AND EQUATIONS

 
FAE1 - 3 Phase Formulae

Adobe PDF

Download this page in PDF

FAE2 - Physical Contraints

FAE3 - Formulae

FAE4 - Unit Conversions
Great care must be exercised in the use of units as the application of incompatible units probably constitutes the major cause of errors in calculation. This section gives some conversion factors to facilitate the expression of units on a common correct base.

Use of the International Standard (SI) units has become mandatory in the R.S.A. in terms of the Measuring Units and National Measuring Standards Act No. 76 of 1973 from the 5th of July 1974 as noted in Government Gazette No. 4326. This system must, therefore, be adhered to on all drawings, specifications, enquiries, contracts and orders.

The SI units consist of:

a) Base units
b) Supplementary units
c) Derived units

FAE5 - Inits of Measure

FAE6 - Delivered Units
 

Technical Information on Key Products
Click on any TITLE in BLUE TYPE for details
============================ KEY PRODUCTS ====================================================================
————————— ALUMINIUM ALLOY TUBULAR BUSBARS ———————————————-
Aluminium Alloy Tubular Busbars

TECH INFO: ALUMINIUM ALLOY TUBULAR BUSBARS

 
The series 6000 aluminium alloys (e.g. 6061) are most often purchased in the T4 condition (not artificially aged) and stored for some period of time before the tube bending operation.

We recommend that client be told of the significance of storage and the consequences of natural ageing whenever advising the purchase of tube in the T4 condition. We would advice that forming and bending operations preferably be conducted within 2 days of receipt. If this can’t be effected, storage of tube in a cool place will be off assistance.

Heat treatable alloys are softer and more ductile immediately after quenching than after ageing. As the ageing process starts relatively quickly for many allows, production schedules must permit forming operations before appreciable natural ageing occurs. As alternatives the parts may be stored under refrigerated conditions to retard ageing or they may be restored to the near fully quenched condition by reversion treatments that dissolve the Guinier-Preston (GP) zones.

The impact of natural ageing is illustrated by data related to 6061-T4. The assumption used is that extrusions are delivered within 10 – 24 hours of pressing, 10 – 24 hours of pressing, 10 hours taken as the base point for the data. If stored at a temperature of 20°C, by six weeks the elongation characteristics decrease by about 20%, the tensile strength increasing by 45%. Five days after (10 hour) delivery the tensile strength will have increased by some 30%. The yield figures are similar. Five days after (10 hour) delivery the yield strength increases by 25%, after six weeks 40 – 45% and after 14 months, 55%. Thus the major effects of natural ageing are achieved quickly.

Higher storage temperatures will increase the rate of ageing, lower temperatures decrease it. Stored at 0°C, the 5 day yield strength would be similar to the 10 hour strength under room temperature. At +20°C the natural ageing process ceases, thus the strength at five days, at six weeks and at 14 months would be some 35% below the normal 10 hour strength.

Thus the storage time and temperature is an important condition for those clients who wish to form the aluminium tubular busbar. The above information is provided by the Aluminium Federation of Southern Africa and is meant to help clients understand the implementation of the natural ageing of aluminium alloys to avoid unexpected problems.

Adobe PDF

Download this page in PDF

 

————————— BI-METAL CLAMPS ————————————————————–
Bi-Metal Clamps

TECH INFO: BI-METAL CLAMPS

 
INTRODUCTION
The copper current currying clamps as depicted in this section are manufactured from the material grade LG 2 in accordance with BS 1400.1969. All clamps are supplied hot tin dipped and can be supplied silver plated if required.

1. Calculation of Thermal Expansion in Copper Tubes in mm

Tech_bi-metal_thermal_expansion_ti_bi_cc1

2. Nominal Linear Expansion of Tubular Busbars
Tech_bi-metal_nominal_linear_expansion_ti_bi_cc2

Adobe PDF

Download this page in PDF

 

————————— BOLTED COMPRESSION CLAMPS —————————————————-
Bolted Compression Clamps

TECH INFO: BOLTED COMPRESSION CLAMPS

 

GENERAL FEATURES

A current carrying clamp can only satisfactorily serve the function that it is designed for, which is the transferral of current flow from one busbar to another, by the optimum design of the contact surface areas coupled with the contact pressure exerted through the clamping covers and their associated clamping systems. Intensive research both in South Africa and in Europe, has resulted in the design of the clamps detailed in this section, such clamps being designed for use at 765kV and capable of carrying current loads in excess of 3 500 amps on a continuous basis. The clamps as shown comply with the requirements of the West German specification number VDE. 0220 and the Eskom (SA) specification number NWS1671. General features of these clamps are:

1. The Compression Tube

The SABS report number 771/8322/R46, “Testing of Line Clamps” clearly shows the best method of making electrical connections to multi-layer aluminium conductor to be the compression technique. In fact, the SABS experiments yielded the following mean percentage increase in voltage drops over the entire aging test carried out on a variety of different current carrying clamps:

  • Compression Tube 40.80%
  • Three bolted clamping covers 48.50%
  • Explosive wedge compression 75.63%
  • Single bolted clamping cover 182.60%

The compression tube incorporated in bolted compression clamps is specially produced for this application. It is precisely dimensioned in accordance with the “compression efficiency formula” resulting from years of research in Europe. To ensure correct installation, it is indelibly marked with the appropriate conductor size, the crimping die reference number and the required points of compression. It is supplied with an internal coating of the correct compression grease.

2. Bolted Clamping Covers

Although compression tubes should be used for stranded conductor connections wherever possible and bolted joints reserved for attachment is feasible, the nature of the tee clamp necessitates the use of a bolted connection on the “run” conductor. Thus special care must be taken with this clamp half.

On installation, micro-contacts are formed between the clamp body and the conductor. The summated areas of these individual micro-contacts make up the total actual contact area. This area only amounts to between 1% and 5% of the apparent, or overlap, surface. Thus, if the permissible current density is 10 amps/mm², this must be interpreted as approximately 0.2 amps/mm² of overlap surface.

The quality and life of the connection is determined by the actual contact area formed on installation and the preservation of such contact area. The contact area can reduce with time and one of the prime causes of this is creep of the conductor material – particularly for large diameter conductors with four or more strand layers. The covers fitted to these clamps are made of carefully selected alloys, gravity die cast or drop forged to yield the ideal strength and elasticity characteristics so that a high residual contact pressure is maintained. The number of clamping covers per connection depends on the current loads of the conductors and on whether stranded conductors, tubes or studs are to be connected.

3. The Clamp Body

The clamp body is provided with a large conductor seating area, machine-grooved for penetration of the conductor oxide layers and the creation of increased actual contact area. They further assist in the distribution of the bolt forces over the entire clamp length. Bolts are locked into the clamp body, thus requiring tightening of the nut only.
The body is indelibly marked with the clamp type number and conductor size.

4. The Welded Joint

Intensive research into welding techniques, both hand and machine methods, has resulted in joints of high quality. Tests in South African and European laboratories show the connection to be physically, electrically and mechanically sound. On-going quality assurance procedures adopted by McWade Productions guarantee that no problems will arise in this area, or for the unit as a whole.

5. Run and Tap Configuration

International understanding is that the RUN conductor (immaterial whether stranded or tubular conductors) is always in the horizontal plane and that the TAP conductor (whether stranded or tubular conductor) is in the vertical plane – see sketch below.

Tech_bolted_compression_ti_bc
The K type cross clamp is specifically designed for use with a SOLID EQUIPMENT STUD and STRANDED CONDUCTORS. The K clamp is manufactured in compliance with the Eskom NWS 1671 specification, which specification calls for one half of the clamp having both the horizontal and vertical cross grooves smooth bored to suit 26 or 38mm dia equipment studs – with the other half of the clamp having the horizontal and vertical cross grooves either machined or cast serrated to suit stranded conductors of 16.3, 19.0, 21.0, 26.5 and 38.5mmdia. These are the standard Eskom stud and conductor diameters and the McWade manufactured K clamps are manufactured to suit these stud and conductor sizes where in all instances the stud is normally classified as the tap side of the clamp, immaterial of whether the stud is vertically or horizontally mounted.
Where a standard K clamp is required to be used with either different conductor or stud sizes, the standard K clamp as manufactured requires to be modified to suit these different stud/conductor sizes. It is required that customers specify both the RUN size and the TAP size in each specific case.

6. Preferred South African Substation Conductors

A.) ASCR Conductors to BS.215

Tech_bolted_compression_ti_bc2
NB.: Above current ratings are based on a wind speed of 1.6 kms per hour and at an ambient temperature of 40°C (the 75 and 90°C temperatures in the above table refer to the conductor temperature).

INSTALLATION PROCEDURE

All inter-connector clamps as manufactured by McWade Productions are designed to suit both the electrical transfer current carrying capacity of the stranded/tubular busbar it is to be utilised with and the mechanical strengths associated with the rated short circuit current.
All international manufacturers’ inter-connector clamps can only perform to their designed electrical and mechanical functions subject to the correct on-site installation procedures being adhered to which are:

1. Clamp Selection

The first step is to ensure that the clamp to be utilized is suited to the application in question. McWade clamps are all stamped with both Type Number and Conductor sizes and these can be compared to those specified on the installation drawings. It should be noted that types KC and YC are to be used solely for the compression connection of conductors to equipment terminals. The only time a bolted connection is made to stranded Conductors is in the case of TEE joints or tap-off where the clamp types T, TC or K are utilised.

2. Cleaning Procedure

All clamps are supplied ex-factory in heavy duty heat-sealed plastic bags and the clamps should only be removed from these plastic bags immediately prior to installation and after correct cleaning and preparation of the installation connection area.
Aluminium alloys as utilised in stranded or tubular conductors are prone to immediate oxidisation after extrusion. This oxide layer can achieve a maximum thickness of 500 – 1000nm and acts as an insulating medium. The dynamics of an oxidised aluminium connection results in a very high resistance interface and causes thermal instability leading to connection failure. To ensure proper contact between the busbar and clamping contact areas, it is necessary to clean away the layer of aluminium oxide in the contact areas.

Preparation of Contact Surfaces

Tech_bolted_compression_ti_bc3
ALL CONTACT SURFACE AREAS must be strongly brushed with a steel-wire brush alternatively with an aluminium oxide emery cloth grade 80 – 180 and then wiped clean with a dry cloth. Immediately thereafter the contact surfaces of the stranded/tubular busbar and inter-connector clamp are to be greased with a high-melting point non-oxidant grease to a 0.25 – 0.5mm minimum thickness. This greasing process must be immediately followed up with the application of the inter-connector clamp to the respective busbars.

Care should be taken that the contact surfaces, which have been cleaned and greased, are kept free of sand and other foreign matter. In the case of accidental pollution these surfaces shall be cleaned with a suitable solvent and the cleaning and greasing process repeated.

Equipment terminal studs and palms whether of aluminium or plated copper are to be cleaned in accordance with the above procedure.

Certain compression compounds contain an aluminium grit and upon compression of the conductor sleeve on conductor, the compressive force drives the grease, containing sharp metalgrit particles, between the conductor strands, at the same time forcing the conductor strands into a semi hexagonal shape, this effect breaking down the oxide film around the inner conductor strands and providing for a point-point contact.

3. Clamp Installation

When installing the inter-connector clamp, ensure that the conductor seating areas match those of the busbar that the clamp is to be fitted to. In cases where the aluminium tubular busbar is slightly beyond the tolerances for diameter and ovality, the clamp can be accurately bedded onto the tube by hammering around the outside of the clamp body shell with a rubber hammer. This can only be done whilst the clamp is clamped onto the tubular basbar and the bolts are to be re-set afterwards with a torque wrench.

4. Clamping Sequence

Once the caps are correctly positioned, final bolt tightening is to take place according to defined sequences in order to apportion correct stresses to the conductor/tubes as well as the inter-connector bodies.

Tech_bolted_compression_ti_bc4
5. Positioning of the Caps
It is imperative that the clamping covers are tightened down in a parallel sequence so that the gap between the clamp’s body and the clamp’s cover is equal on both sides

Tech_bolted_compression_ti_bc5
6. Bolt Tightening Torques

All clamps are fitted with bolts, nuts and washers of either:

a) 8.8 grade high tensile steel bolts (HDG),
b) Stainless steel grade A2/A4,
c) Aluminium alloy grade 7075 – P60.

All inter-connector clamps are designed to provide a maximum effective contact surface between the busbar and the inter-connector clamp for the efficient transfer of electrical current. This maximisation of effective contact surfaces can only be achieved by the correct contact pressures of >6N/mm² being applied to the clamp. This can only be achieved by all bolts being tightened with a torque wrench to the required torque as stated below:

Tech_bolted_compression_ti_bc6

7. Compression Joints

The conductor size to be compressed must correspond to the conductor diameter stamped on the compression tube. The conductor is to be cleaned as stated above and then cut to the required length. It is inserted into the pre-greased compression tube until the end is firmly against the clamping body stop. Compression is to be undertaken using a suitable 30/45-ton rating power operated compression tool. Compression dies are to be checked to meet with the following sizes:

Hexagon Type Crimped Connections

Tech_bolted_compression_ti_bc7
Note: These are the commonly used Conductors in Sub-stations in South Africa. For all other connections, information is available on request. Dies reference numbers are to be checked to the number stamped on the compression tube. Compression of the tube and conductor should commence from the conductor end towards the clamp body and compression must be effected over the compression marks detailed on the tube.

Compression tools are to automatically bypass on complete compression and under no circumstances should the die pressure be released before bypass is reached. After full compression the die numbers 42 or 58 will be imprinted onto the tube and serve to indicate both satisfactory and complete compression.Compression tools are to be treated strictly in accordance with the operating instructions supplied.

A light film of pure white Vaseline should be applied to the compression die faces after every 5 – 10 compressions in order to extend die life and facilitate die slide over the compression tube surface. Any compression die flashes should be removed with a file.Upon completion of the clamp installation and checking that all bolts are correctly torqued surplus grease should be wiped away.

Adobe PDF

Download this page in PDF

 

————————— CONDUCTORS ——————————————————————-
CONDUCTORS . . .
___________________________ CONDUCTORS: STEEL _________________________________________
Conductors: Steel

TECH INFO: CONDUCTORS: STEEL

Please click on diagram below to view larger version.
Tech_conductors_Steel_p020_1_01

Adobe PDF

Download this page in PDF

 

___________________________ CONDUCTORS: ALUMINIUM _____________________________________
Conductors: Aluminium

TECH INFO: CONDUCTORS: ALUMINIUM

Please click on diagram below to view larger version.
Tech_conductors_aluminium_s

Adobe PDF

Download this page in PDF

 

___________________________ CONDUCTORS: ACAR __________________________________________
Conductors: ACAR

TECH INFO: CONDUCTORS: ACAR

Please click on diagram below to view larger version.
Tech_conductors_acar_s

Adobe PDF

Download this page in PDF

 

___________________________ CONDUCTORS: AAAC __________________________________________
Conductors: AAAC

TECH INFO: CONDUCTORS: AAAC

Please click on diagram below to view larger version.
Tech_conductors_aaac1_s

Adobe PDF

Download this page in PDF

 

___________________________ CONDUCTORS: ACSR __________________________________________
Conductors: ACSR

TECH INFO: CONDUCTORS: ACSR

Please click on diagram below to view larger version.
Tech_conductors_acsr1_s

Adobe PDF

Download this page in PDF

 

___________________________ CONDUCTORS: ANNEALED COPPER STRANDED ______________________
Conductors: Annealed Copper Stranded

TECH INFO: CONDUCTORS: ANNEALED COPPER STRANDED

Please click on diagram below to view larger version.
Tech_conductors_annealed_cop_stran_cond1_s

Adobe PDF

Download this page in PDF

 

___________________________ CONDUCTORS: COPPER ANNULAR CROSS-SECTION __________________
Conductors: Copper Annular Cross-section

TECH INFO: CONDUCTORS: COPPER ANNULAR CROSS-SECTION

Please click on diagram below to view larger version.
Tech_conductors_copper_cond_annular_s

Adobe PDF

Download this page in PDF

 

___________________________ CONDUCTORS: COPPER ROUND CROSS-SECTION ____________________
Conductors: Copper Round Cross-section

TECH INFO: CONDUCTORS: COPPER ROUND CROSS-SECTION

Please click on diagram below to view larger version.
Tech_conductors_copper_cond_round_s

Adobe PDF

Download this page in PDF

 

___________________________ CONDUCTORS: HARD DRAWN TO SABS 182 ________________________
Conductors: Hard Drawn to SABS 182

TECH INFO: CONDUCTORS: HARD DRAWN TO SABS 182

Please click on diagram below to view larger version.
Tech_conductors_sabs182_s

Adobe PDF

Download this page in PDF

 

___________________________ CONDUCTORS: MAX CURRENT OF FLAT BUSBARS ___________________
Conductors: Max Current of Flat Busbars

TECH INFO:CONDUCTORS: MAX CURRENT OF FLAT BUSBARS

Please click on diagram below to view larger version.
Tech_conductors_flat_busbars_s

Adobe PDF

Download this page in PDF

 

————————— TUBULAR BUSBAR CLAMPS ——————————————————-
Tubular Busbar Clamps

TECH INFO: TUBULAR BUSBAR CLAMPS

 

INTRODUCTION

The aluminium alloy tubular bus current carrying clamps depicted in this section are manufactured in certified aluminium alloys, namely aluminium alloy grade LM-6 as a standard, alternatively in aluminium alloy LM-25 heat treated to a T6 temper where a clamp is required to comply with a higher strength rating.

Tubular Busbar

Standard South African busbar tubes are supplied in either the alloys 6101-A and/or 6261-TF which are both suitable for electrical purposes. The 6261-TF alloy has better mechanical properties, but somewhat poorer electrical properties than the 6101-A. However, for application of HV yards, where long spans are essential, the 6261-TF alloy with superior mechanical properties is preferred. All imported Aluminium Alloy Tubular Busbar are in the grade 6101-BT6.

Tech_tubular_busbar_clamps_ti_tbc1

INSTALLATION PROCEDURE

When installing full or half expansion inter-connector clamps, care must be taken for the allowance of the thermal expansion of the relevant basbar tube, be it aluminium or copper. An estimate of the expansion of various tubes due to thermal expansion at various temperature changes is given in the tables below:

1. Calculation of Thermal Expansion in Aluminium Tubes in mm

Tech_tubular_busbar_clamps_ti_tbc2
Temperature Co-efficient of Linear expansion (temp. range -20° + 200°C
Aluminium: 23 x 10-6 (0,000023 per centigrade degree)

Example of the Calculation of Thermal Busbar Expansion:

Aluminium basbar tube, length = 10m

Temperature difference t = Max. Op. Temperature – Min. Op. Temperature

= (+80°C) – (-20°C)

t = 100°C
Assembly temperature = +20°C

For complete expansion length refer to table = 24.0mm.

Temperature difference between the final temperature (+80°C) and the assembly temperature (+20°C) is therefore 60°C. Referring to the above table, the corresponding expansion difference will be 14,4mm. The clamp must therefore be mounted in such a way that a shift of at least 14,4mm in the direction of the clamp centre is guaranteed. A shift in the opposite direction in accordance with the temperature difference of (+20°C) assembly temperature and (+20°C) being the lowest final temperature – 40°C. Referring to the above tables, this value is given as 9.6mm.

2. Short Circuit Forces on Clamps

Tech_tubular_busbar_clamps_ti_tbc3
Notes: * Indicates the phase spacing at which maximum short circuit forces occurs.
Clamps are designed to have a factor of safety of 2:1 with respect to the specified load. Unless the min. mechanical load is specified, the standard strength LM-6 alloy clamp, is supplied.

3. Busbar Tube Vibration Damping

Aluminium tubular busbars are subject to wind-generated vibration and oscillation. Because of the low self-damping of tubular busbars very slight excitation forces will suffice to excite the tubes to vibrations amplitudes of the order of the tube diameter, when there is a resilience of the excitation force with a natural frequency of the tube.

These high amplitudes produce additional dynamic stresses inside all structural parts and it is often necessary to dampen this tube oscillation by the insertion of AAC conductor into the busbar. The increased self damping provided by the insertion of damping conductor delays the onset of resilience build-up and this limits the maximum amplitudes created by a given excitation force.

As a rule it is normally sufficient to insert one conductor into a tube, but in order to increase the safety and to maintain maximum damping effect it is advisable to insert two conductors into the tube (one at each end running for 2/3 of the tube length). The following table shows recommended damping conductor sizes. A drain hole of 10mm diameter should be drilled at bottom centre point of tubes to facilitate drainage of condensate moisture.

Tech_tubular_busbar_clamps_ti_tbc5n
4. Nominal Linear Expansion of Tubular Busbars

Tech_tubular_busbar_clamps_ti_tbc6

Adobe PDF

Download this page in PDF

 

————————— TRANSMISSION LINE HARDWARE ————————————————–
Transmission Line Hardware

TECH INFO: TRANSMISSION LINE HARDWARE

McWade Productions manufactures and supplies a comprehensive range of hardware fittings utilised in the make-up of complete insulator string sets for both LV/HV transmission lines and substations up to an operational voltage of 800kV.
All forged steel hot dipped galvanised fittings are manufactured in compliance with IEC specification number IEC120.

The catalogued range of compression connectors provides for service and heavy duty “T” connections from Main Lines. Connectors are available for COPPER ALUMINIUM and BI METAL interconnections between Main Line conductors and branch cable. Live Line bails are included in the range, since these provide for disconnectable features at Overhead Line section points, or any situation where live clamp tapping of the conductor is desirable.

The types of connector designs available ensure the complete requirements of HV and LV tapping are catered for with a minimum number of “Range Taking” compressed with the “Bimetal 4” No Die Crimping Tool.

Accessory equipment such as:

  • Tensioning Machines
  • Lifting Apparatus
  • Hot Line Working Tools
  • Grounding/Earthing Equipment
  • Cover up equipment
  • Working Platforms
  • etc. are sourced from both local and internationally recognised suppliers.

Adobe PDF

Download this page in PDF

 

Miscellaneous Items
Click on any TITLE in BLUE TYPE for details
==========================MISCELLANEOUS ITEMS ===============================================================
————————- ALUMINIUM TUBULAR BUSBAR FOR HV SUBSTATIONS ————————————-
Aluminium Tubular Busbar for HV Substations

TECH INFO: ALUMINIUM TUBULAR BUSBAR FOR HV SUBSTATIONS

In many instances HV outdoor substations with a high current rating are constructed more economically with aluminium tubular busbars rather than with stranded conductors. The advantages realised by using aluminium tubular busbars are:

Busbars are lighter in weight and have a greater stiffness than stranded conductors with the same current transfer capacity. This facilitates larger free spans which:

  • Require fewer points of supports and foundations
  • Impose a lower mechanical load on the foundation points and circuit equipment than stranded cables do under short circuit conditions
  • Are good electrical conductors due to the skin effect: the busbar surface has a current density that is relatively lower than that of a stranded conductor
  • Are permanently corrosion resistant
  • Possess excellent electric conductance properties
  • Have a smooth surface
  • Maintenance free
  • Have a very long life span

Tubular busbars can be welded together to provide a total length of about 140 meters.

In Southern Africa aluminium tubular busbars up to a nominal diameter of 160mm with a wall thickness of 8mm can be locally manufactured and provided up to maximum lengths of 12 metres. Larger diameter lengths of tube are supplied by the company out of recognised foreign manufacturers.

The following information relates to imported aluminium tubular busbars manufactured in accordance with Standard EN 755-2.

Using the information detailed hereunder, you can calculate which specifications the aluminium tubular busbars used in your projects must meet. The guidelines and methods of calculation detailed have been determined by KEMA of the Netherlands.

It is assumed that the client knows the following details:

  • The nominal current during normal operation
  • The required short-circuit current
  • The applicable centre-line distance between busbars
  • The Maximum span between two busbars supports

Based on these details a correct choice of busbar diameter and wall thickness can be made using the method described below.

The dimensions of a busbar are mainly determined by two physical loads, i.e. the thermal and mechanical loads on the busbar.

MATERIAL PROPERTIES

The alloys listed below, which comply with EN 755-2, are those most commonly used for electrical busbars. Alloy 6101B T6 has more mechanical strength but less electrical conductivity. If higher electrical conductivity is required, alloy 6101B T7 can be used. However, this alloy has less mechanical strength. Of course busbars made of other alloys can also be supplied.

Tech_Misc_aluminium_tubular_ti_atb1
THERMAL CAPACITY OF BUSBARS

The thermal capacity of a busbar is mainly determined by:

  • the environment: temperature and solar radiation
  • the nominal current
  • the maximum busbar temperature as determined by the client

When the amount of heat absorbed by the busbar is the same as the amount of heat it emits, equilibrium is reached. In this situation the busbar temperature will remain constant. The current at this point of equilibrium is the current-carrying capacity of the busbar.

This heat balance must be considered under normal operating conditions and under the extreme condition of a short-circuit. During a short-circuit extra heating of the busbars may occur in a short space of time.

Normal operating conditions:

In this documentation the allowable current was calculated in accordance with DIN43 670 with an ambient temperature or 35ºC, a final busbar temperature of 80ºC, an absorption coefficient of 0.6 and a solar radiation of 600 W/m².

The allowable current for the busbar dimensions and standard aluminium alloys available are given in table 2 and table 3.

It can be seen from the tables that when using aluminium alloy 6101B T7 for a current carrying capacity of 3000A, the minimum busbar dimensions (diameter/wall thickness) of 100/10, 120/6 or 160/4 are acceptable.

For different ambient temperatures or final busbar temperatures the current carrying capacity can be determined using the load factor from figure 1.

Example:
At an ambient temperature of 30ºC and a final busbar temperature of 65ºC, the current carrying capacity from table 2 or 3 has to be multiplied by a factor 0.86.

If, under these conditions, a busbar has to be selected for a nominal current of 3000A, the method is as follows:

  • The effective load on the busbar is 3000 : 0.86 = 3488 A
  • From the table (6101B T7) it can be seen that possible choices for busbar dimensions are 120/10 or 160/5

Figure 1. Current carrying capacity as function of ambient temperature and final busbar temperature.

Tech_Misc_aluminium_tubular_ti_atb2
Short-circuit

Under short-circuit conditions the final busbar temperature must not exceed 200ºC, based on an initial temperature of 80ºC. Higher temperatures can affect the structure of the aluminium alloy, which results in changes in its mechanical properties. During short-circuits the temperature will generally remain below the allowable temperatures of 200ºC, based on a busbar temperature of 80ºC during normal operation.

After determining the busbar cross-section the current density during a short-circuit can be determined. This current density (J) can be determined from the short-circuit 1K and the cross-section of the busbar.

Table 1. Current density (J) as a function of material type and duration of the short-circuit current.

Tech_Misc_aluminium_tubular_ti_atb3
MECHANICAL CAPACITY OF BUSBARS

The busbar’s diameter and wall thickness are not determined on the basis of the current carrying capacity only. The sag as a result of normal and exceptional loads must also be taken into account.

In accordance with the harmonisation document “HD 637 Power installations exceeding 1kV a.c.”, busbars must meet mechanical requirements that have been derived from the following loads and operating conditions:-

Normal loads taking into account:

  • the busbar’s mass
  • ice load
  • wind load

These loads determine the sag of the busbar under normal operating conditions. The amount of sag depends on the stiffness of the busbar. If the busbar’s diameter and wall thickness are determined, the sag under normal operating conditions can be determined. This can be important for the design of a switchyard.

The sag resulting from the mass and span length of the busbar can be determined from figure 2.

Figure 2. Busbar sag as function of span length (as a result of the mass of the busbar itself)

Tech_Misc_aluminium_tubular_ti_atb4
Exceptional loads, taking into account:

  • short-circuit forces
  • switching forces

Only forces on the busbar during short-circuits are considered below, since these forces are the determining factor in most cases.

In a three-phase system with three busbars in the same plane, the greatest force during short-circuits will occur in the centre busbar. Electromagnetic forces will occur between the conductors as a result of the short-circuit current. The busbar must have a certain stiffness to absorb these forces. The required section modulus was determined in accordance with the simplified calculation method of IEC 865.

Based on the required short-circuit current and phase-to-phase distance, the electromagnetic force per metre busbar can be determined using figure 3 and figure 4 (depending on the alloy used). With this data and the required span length the required section modulus can be seen.

The calculations are based on:

  • a two-point support for the busbar
  • a factor of plasticity of 1.4
  • automatic re-closing after the short-circuit

DETERMINING THE BUSBAR DIAMETER AND CROSS-SECTION

With the required nominal current-carrying capacity and the required section modulus one or more suitable busbar dimensions that meet both requirements can be found in table 2 or 3.

Example of determining a busbar dimension:

Criteria

Inormal:4000Anominal current during operation
Ik:50kAshort-circuit current
aphase-phase:4mphase-phase distance
Lmax:12mspan length, distance between supports
Al alloy:6101BT6

The following busbar dimensions (diameter/wall thickness) are acceptable for the required nominal current of 4000 A:120/15, 160/8, 200/5 and 220/4 (see table 2).

Using figure 3 it can be determined that, at the given short-circuit current, phase-to-phase distance and span length, the required section modulus is approximately 100cm³. Among others, the following busbar dimensions meet this requirement: 120/12, 160/6, 200/5 and 220/4.

Busbars 120/15, 160/8, 200/5 and 220/4 meet both the current carrying capacity requirements and the requirements from the dynamic short-circuit load. Busbar 220/4 is the lightest in weight but is vulnerable due to its small wall thickness. Therefore a choice should be made between 120/15, 160/8 or 200/5.

After determining the diameter and wall thickness, the client’s choice of busbar may be based on the following:

  • Weight saving
  • Standardisation of busbars to be used (possibly a preference for 120mm type)
  • Sag of the busbar as a result of busbar mass (see figure 2)
  • Current density in the busbar as a result of short-circuits (see table 1)
  • Ease of working on the busbar (it is easier to weld termination pieces to busbars with greater wall thickness)

Changing assumptions or parameters can be discussed with KEMA, if required. Optimisation can lead to significant savings, not just on busbar material but also on supports, e.g. lighter insulators, support structures and foundations. To this end, KEMA has advanced calculation methods and tools at its disposal.

TUBE OPERATIONS

Aluminium tubular busbars are subject to wind-generated vibration and oscillation. Because of the low self-damping of tubular busbars very slight excitation forces will suffice to excite the tubes to vibration amplitudes of the order of the tube diameter, when there is a resilience of the excitation force with a natural frequency of the tube. These high amplitudes produce additional dynamic stresses inside all structural parts and it is often necessary to dampen this tube oscillation by the insertion of AAC conductor into the busbar. The increased self damping provided by the insertion of damping conductor delays the onset of resilience build-up and this limits the maximum amplitudes created by a given excitation force.

Tech_Misc_aluminium_tubular_ti_atb5

Adobe PDF

Download this page in PDF

 

————————— APPLICATION OF CONNECTOR ON CONDUCTOR —————————————–
Application of Connector on Conductor

TECH INFO: APPLICATION OF CONNECTOR ON CONDUCTOR

CHECK LIST

1. Hydraulic tool (No leaks, in good working order)
2. Fitting (Size is correct)
3. Conductor size
4. Wire brush
5. Grit grease 159 G
6. Cable cutter

PROCESS

1. The conductor should first be cut off square and clean, then straightened by hand (no hammer etc.) as all conductors have a curve built-in, due to it being placed on a drum. Should you not straighten the conductor it will lead to this curving (bananing) when crimp

To make a perfect joint CUT the conductor leaving a clean square end.

Tech_Misc_appl_of_connector_on_conductor_1_p048_1_01
2. Now clean the area where the fitting is to be attached by means of the wire brush, even if the conductor is new, it will already have oxidized and it is for this reason that the grease is applied, to prevent oxidation. Apply grit grease after cleaning.

CLEAN the Conductor

3. Select compression fitting, remove from packaging and remove plastic caps insert conductor, and revolve fitting to apply grit grease to both surfaces.

Tech_Misc_appl_of_connector_on_conductor_2_p048_1_00
PUSH the conductor fully into the connector and revolve fitting. REVOLVE FITTING.

Tech_Misc_appl_of_connector_on_conductor_3_acc3
4. Now follow instruction on fitting with regard to crimping procedure and how many crimps. (Crimp between lines) all fittings which are required to join two conductors in line will have a center stop, so that the operator will not over crimp one and under crimp the other. CCL fittings are crimped in the middle for this purpose and to act as a guide as to how deep the indent should be, if a conductor is inserted and crimped. Should the conductor be able to pass through the indents, the conductor diameter is in fact too small for that particular fitting.

Tech_Misc_appl_of_connector_on_conductor_4_acc4

Adobe PDF

Download this page in PDF

 

————————— FITTINGS FOR BIMETAL 4E SYSTEM ————————————————
Fittings for Bimetal 4E System

TECH INFO: FITTINGS FOR BIMETAL 4E SYSTEM

1. All raw material is checked for hardness, elongation, malibility before any fittings are manufactured.

2. All fittings are locally made with 100% local content.

3. All fittings are de-oxidized and cleaned before being dispatched, to remove an oxidation in and outside the tube.

4. All fittings are marked as follows:

   a) Manufactures name-CCL

   b) Type of material

  • Aluminium
  • Copper
  • Bimetal

   c) Fitting type

  • Non tension joint
  • Tension joint
  • Angle tap connector
  • Tee tap connector
  • Lugs (1 hole lugs)
  • Jumper terminal (2 hole lugs)
  • Tee flag connector
  • Repair sleeve
  • C Connector
  • Bi-metal lugs & Ferrols
  • Dead ends

   d) All fittings are designed exclusively to fit and operate the “Bimetal 4” Compression system. With the following sizes-
Range of Conductors

  • 0 = Squirrel4,0-7,0
  • 1 = Fox6,0-8,5
  • 2 = Mink/ Pine8,0-11,3
  • 3 = Hare/ Oak10,0-14,00
  • 4 = Hornet12,0-16,00

   e) Size of tap connector

   f) What tooling to be used and where to crimp

5. All fittings have a manufacturers code build-up from the above description. i.e.: VCAT 1.2 (code 1022)

Tech_Misc_Fittings_for_Bimetal_4E_System_ti_ffb1
6. All fittings are pre-greased with 159 grit grease before being capped and packed in see-through plastic packages, hermetically sealed to prevent air and moisture gaining access to the fittings.

Adobe PDF

Download this page in PDF

 

————————— INSULATORS GENERAL FEATURES —————————————————
Insulators General Features

TECH INFO: INSULATORS GENERAL FEATURES

 
Polymer Insulators

Elbroc polymer insulators have been ergonomically designed and shaped to make use of the environment and its changing conditions to create insulators that are:

  • Self washing
  • Light weight
  • Easy to use

There are more of this design of composite insulators in service than all other makes combined.

Elbroc polymer insulators were first installed in SA on a 132kV line in the Nelspruit area in 1979. Some of these were subsequently taken down for examination and testing, and were found to be in perfect working order. Random checking over the years has confirmed the reliability of Elbroc polymer insulators.

This reliability helps you to satisfy your customer’s need for uninterrupted power supply.

Field use has proved that Elbroc composite insulators are the cost effective, high performance solution to the ongoing maintenance and construction problems encountered in the distribution of power.

Elbroc polymer insulators, which are marketed under the trade name “Thiel-Lite”, are manufactured under licence to the world-renown Ohio Brass Company of America who are leaders in polymer technology. Our licence agreement ensures that all new product developments are immediately incorporated into the local product.

Our manufacturing and marketing policy includes a quality assurance programme that is in accordance with our listing in terms of SABS ISO 9001 code of practice, ensuring that our products conform to the high standards demanded by the industry we serve.

More than 500 000 units sold in the first 14 years.

Basic Construction

The insulators consist of three basic components:

  • Weathersheds
  • Fibreglass rod
  • Metal end-fittings

The weathersheds are assembled over the fibreglass rod, the centre hole in the weathersheds being smaller than the rod to ensure a tight fit. The inner surface of the weathersheds hole forms two O-rings per centimetre and the reservoirs between these O-rings are filled with a special silicone grease to produce a continuous, permanent “living” seal.

The end fittings are attached by crimping them to the fibreglass rod.

When assembled, the end-fittings maintain the entire stack of weathersheds under axial compression, which adequately compensates for the slight elongation of the fibreglass rod under tension or when temperature changes occur.

A wide range of products for 11 to 765kV are available to fit all existing hardware. Applications stretch from the sub-zero temperatures of Alaska to the harsh UV conditions of the Namibian desert.

Local manufacture gives you:

  • Custom design. We manufacture to your needs (all configurations from 11 to 20mm socket/ball and clevis/tongue).
  • Better deliveries because there are no long shipping times.
  • Superior local knowledge of polymer insulator design and construction.
  • Price flexibility.
  • Production flexibility.
  • Direct replacements for existing strings.
  • No change in ground clearances.
  • Reduced down time and fewer outages.
  • Less fault tracing.
  • Cheaper transportation.
  • Improved productivity.
  • No repetitive line inspections. Once a McWade insulator is installed you never need worry again. “Put it up and leave it”.
  • Maintenance down time is costly. McWade polymer insulators help you save money.

Tech_Misc_insulators_general_features_ins1
Section Lengths Available

McWade strain and suspension insulators are available in lengths appropriate for 11kV through 132kV. Longer or shorter lengths can be produced for special projects. Length increments are approximately 38mm.

Insulation Co-ordination

The operating performance of a transmission line depends on its insulation level. It must not flash over under practically any operating condition. Several methods of co-ordination of line and station insulation have been proposed. Generally, the best method is to establish a definite common insulation level for all the station insulation and then match that level with the line insulation. With this approach, the task is limited to three fundamental requirements:

  • Selection of Basic Insulation Level (BIL)
  • Specification of insulation with flashover characteristics equal to or greater than the selected BIL and
  • The application of suitable over voltage surge protection

Satisfactory performance is generally achieved with an insulator which has a dry 60Hz flash over of three to five times the phase-to-ground voltage and a leakage distance approximately twice the shortest air gap (strike) distance.

Corona Performance

McWade suspension and strain insulators are RIV and corona free through 132kV, by the use of integral Stress Distribution Disk (SDD). The table below details the rings necessary for voltages equal to or exceeding that listed in the column header.

Tech_Misc_insulators_general_features_ins2

Adobe PDF

Download this page in PDF

 

————————— INSULATORS PART NUMBER MAKE UP ————————————————
Insulators Part Number Make Up

TECH INFO: INSULATORS PART NUMBER MAKE UP

Tech_Misc_insulators_part_number_makeup_pnmu

Adobe PDF

Download this page in PDF

 

————————— INSULATORS STORAGE & HANDLING ————————————————-
Insulators Storage & Handling

TECH INFO: INSULATORS STORAGE & HANDLING

 
Handling

While these insulators are remarkably resistant to damage, care should always be taken to avoid dragging on the ground, or against structural numbers.

The insulators will accept moderate bending or twisting, but severe bending or torsional loading should be avoided. Bending loads are sometimes easily applied to ball or socket fittings, watch especially for ball shank bending and/or socket cotter crushing.

If rings are to be added, follow manufacturer’s recommendations for position and orientation. This information is provided by a small drawing/tag attached to each ring.

Installation

Always examine insulators for handling and shipping damage.

Install insulators so that moisture will drain from the sheds, the shed angles make this easy in standard line construction. If unique construction requirements – e.g. “uphill deadends”, result in sheds which will not drain, reverse the insulators or use special insulators with inverted sheds. A good rule when the insulator must be installed with upward-sloping sheds is to make sure the insulator position is within 45 degrees of horizontal.

For safety reasons and to prevent insulator damage, crews MUST AVOID climbing on, walking on, or hanging ladders from the insulator surfaces.

Storage

Store insulators in an area free of standing water. Avoid direct contact with transformer oil, hydraulic oil, or other similar petroleum derivatives.

The light weight of the insulators permits storage on light duty floors and foundations. Suspension insulator design encourages vertical storage (hanging or standing), reducing the floor area required. For long units standing vertically, a simple rack may be useful to provide support.

Cleaning

McWade Insulators normally require no cleaning, washing, or other routine maintenance. Chalking of the rubber weathersheds surfaces that are exposed to sunlight is normal and helps protect the polymer surface from the sun’s UV rays. Thus, chalky white surface film need not be removed by cleaning.

Washing or cleaning may be required if the insulators are installed in areas of severe environmental contamination and where there are indications of abnormal leakage currents or scintillation on the insulator surface due to fog, mist, or other conditions of light wetting.

In the event that washing or cleaning is required, the procedures are outlined in ANSI/IEEE 957 “Guide for Insulator Cleaning”

Adobe PDF

Download this page in PDF

 

————————— ISOLATING SWITCHES ————————————————————
Isolating Switches

TECH INFO: ISOLATING SWITCHES

The Isolating Switches as detailed in this catalogue are designed for use in sub-station and distribution lines and categorised as either outdoor 3 phase rocking type and single phase isolators or three phase centre rotating double side break isolating switches.

1. OUTDOOR THREE PHASE ROCKING TYPE AND SINGLE PHASE ISOLATORS

The following switches are manufactured in accordance with IEC 60265-1 and are used in the voltage ranges 11, 22 and 33kV. For each voltage range manufactured we are able to supply a switch with a current rating of 400A up to 1200A depending on the customer’s requirements. The short time (3 second) current ratings for these switches are as follows: 13kA up to 600A & 7.5KA for 800A & 1200A.

These switches can be mounted either horizontally or vertically and are normally supplied with manual insulated operating mechanisms. Motorised or spring operating mechanisms are available on request.

The main characteristics and components of these switches are as follows:

Current Carrying Components

Contacts
Manufactured from high conductivity copper. Fixed contacts are spring backed to ensure high contact pressure. Surfaces on both fixed and moving contacts are nickel plated. (Silver plating is an optional extra up to 600A and standard for 800 and 1200A).

Current Transfer
Current paths with flexible cables which carry current from the fixed insulator (load end) to the tilting centre insulator are supported within a mild steel pantograph.

Main Terminals (connector pads)
Comprise copper pads for acceptance of conductors as specified. The complete assembly is nickel or silver plated depending on the current rating.

Saddle type clamps are provided as standard up to 600A. For 800A and 1200A, pads are drilled to accept compression or bolted type terminals (optional extra).

Arcing Contact
The main moving contact (isolator blade) incorporates an arcing tip which serves to protect the main contacts from burning on closing the isolator, i.e. the arcing contacts close before the main contacts are engaged. The arcing contacts do not carry current when the isolator is fully closed.

Hinge
The centre tilting insulator assembly hinge which is designed to run dry for long periods of maintenance free operation, comprises non-ferrous bearing points and galvanised ferrous surrounds.

Base
Each phase base is manufactured from mild steel channel which is hot dip galvanised to ISO 1461 after fabrication. Mounting holes to suit standard mounting arrangements are provided.

Operation Mechanism
An operating handle of the reciprocating type is supplied. Adjustment of the vertical connecting pipe is easily accomplished by means of a turnbuckle.
Facilities exist for padlocking the isolator either in the open or closed position. Interlocks can be fitted.
The vertical rod between the operating mechanism and the isolator inter phase operating tube is supplied in suitable lengths to facilitate installation, with insulating insert.

Installation Instructions
See the technical section for the installation and operating instruction.

2. 3-PHASE CENTRE ROTATING DOUBLE SIDE BREAK ISOLATING SWITCHES

A range of centre rotating switches is manufactured from 11 – 66kV. These switches can be supplied with a current rating up to 1600A. The short time (3 seconds) current rating for these switches is 25kA.

These switches are mounted horizontally and are normally supplied with manual operating mechanisms. Motorised operating mechanisms are available on request.

The main components of these switches are as follows:

Current Carrying Components

Contacts
Manufactured from high conductivity copper. Contacts are spring backed to ensure high contact pressure. Contact surfaces on both fixed and moving portions are nickel plated. (Silver plating is an optional extra up to 600A and standard for 800 and 1200A).

Main Terminals (connector pads)
Comprise copper pads for acceptance of conductors as specified. The complete assembly is nickel or silver plated depending on the current rating.

All pads are drilled to accept compression or bolted type terminals (optional extra).

Base
Each phase base is manufactured from mild steel channel which is hot dip galvanised to ISO 1461 after fabrication. Mounting holes to suit standard mounting arrangements are provided.

Operation Mechanism
An operating handle of the rotational type is supplied. Adjustment of the vertical connecting pipe is easily accomplished by means of a turnbuckle.
Facilities exist for padlocking the isolator either in the open or closed position. Interlocks can be fitted.
The vertical rod between the operating mechanism and the isolator inter phase operating tube is supplied in suitable lengths to facilitate installation.

Installation Instructions
See the technical section for the installation and operating instruction.

3. GENERAL

Metal Treatment
All ferrous components are hot dip galvanised to ISO 1461. Current carrying non-ferrous components are nickel plated, alternatively silver plated where applicable.

Type Designation
A metal nameplate detailing the isolator type and rating is affixed to each isolator base.

Packing
Each isolator is suitably packed in wooden crates to protect against damage during transport and storage.

Type Test
To substantiate ratings, type test reports are available on request.

Adobe PDF

Download this page in PDF

 

————————— ISOLATORS INSTALLATION & MAINTENANCE ——————————————
Isolators Installation & Maintenance

TECH INFO: ISOLATORS INSTALLATION & MAINTENANCE

 
CHECK LIST

On receipt of equipment compare components against the following checklist. Notify supplier immediately of shortages or damage.

1. Complete isolator per page 2: three phases per unit.
2. Interphase coupling tube – 38mm square tube: 1 length.
3. Vertical operating rods: 20mm bore pipe x 2m lengths: 3 lengths.
4. Operating lever assembly.
5. Operating rod insulating insert
6. Reciprocating operating handle assembly.
7. Flexible earthing strap.

NOTE: In cases where arc chutes have been removed for transportation, refit one to each
Phase as described on page 5 of this pamphlet.

INSTALLATION

Each isolator is factory aligned before dispatch, but to ensure years of trouble free operation, follow these instructions carefully: –

1. Place individual phases in position on the mounting framework. In the case of 11kV and 22kV isolators, ensure that the isolator pole fitted with adjustable hinge stops is mounted in the center phase position. This is important as the open and closed positions for all three phases are set by this phase.

2. Holding down bolts can be inserted, but not secured.

3. Loosen U-bolts on center hinge assemblies on each phase – removal is not necessary.

4. Position interphase coupling tube through square apertures in hinges, ensuring alignment with operating handle position and/or equal overlap through outer phase hinges.

5. Tighten U-bolts finger tight.

6. Open isolator, i.e. separate the main moving contact and the fixed contacts by pulling upwards on the main contact blade. All three contacts will open.

7. Close slowly, letting the moving contacts rest in the fixed contacts. Do not close completely.

8. Leaving the phase coupling tube free, align the three phase bases, and tighten the holding down bolts.

9. Tighten U-bolts on all phases.

10. Close isolator until the center phase moving contact is parallel to the base. Adjust the appropriate stop if necessary. Lock in position. At this point, ensure that the interrupter moving contact (Load break head, item 4) is not making contact with the arc chute internal contacts. It should not be necessary to adjust the open position stop.

11. Open the isolator slowly, checking that the arcing moving contacts have properly latched below the arc chute contacts, and remain below them until the main moving contacts are well clear of their fixed contacts.

12. Close the isolator slowly, checking that the arcing contacts on all phases latch below the arc chute contacts and once fully closed, do not touch them or the bottom of the arc chute. This setting is made by means of the eccentric stop.

13. Clamp the operating lever in the desired position on the phase coupling tube.

14. Place the operating mechanism handle in position, screw up bolts finger tight.

15. Fit rod guide in position on the structure

16. Attach one length of vertical operating pipe to the operating mechanism turnbuckle. Fit insulating insert (if supplied) to operating pipe.

17. Close operating mechanism.

18. Fit remaining operating rods, cutting top section to suit if necessary, Use pipe sockets and U-bolts on operating lever to secure.

19. Align operating mechanism handle and tighten fixing bolts.

20. With isolator in closed position and operating handle in the “ON” position, check that the center hinge is against the closed stop.

21. Tighten the operating mechanism turnbuckle until the operating pipe is taut. Secure in position with lock nuts.

22. Check all fasteners for tightness.

23. By means of operating mechanism, open and close the isolator a number of times to ensure a positive action exists.

24. Secure the operating mechanism earthing strap to the mechanism mounting base.

25. Secure incoming and outgoing conductors as required.

Adobe PDF

Download this page in PDF

 

————————— LIST OF COMPONENTS HK ISOLATORS ———————————————–
List of Components HK Isolators

TECH INFO: LIST OF COMPONENTS HK ISOLATORS

Component List

Tech_Misc_list_of_components_hk_isolators_ti_loc1

Unpacking

The isolators are packed in sub-assemblies, one complete isolator per skeleton crate. The 3-phase sub-assemblies consist of Items 3, 5, 6, 7 and 8, mounted on their phase channel bases (3). In addition items 1, 2, 9, 10 and 12 are strapped to the side of the crate.

Inspect and check the existence of all the above parts and advise supplier immediately of any shortages or damage (see addendum for any additional optional parts).

Installation

1. The contact pressure is factory set. Open moving contacts and close again until contacts just touch. Check that the fixed contact blade is positioned in the centre of the two moving contact blades. If not satisfactory, slacken off M8 screw with spring nearest to the centre insulator. Adjust blades up or down to suit and re-tighten the M8 screw.

2. Mount and align each phase sub-assembly in position on the structure (supplied separately or by others) at the phase centres indicated on the drawing and secure.

3. Position the hand operating mechanism (1) on the structure.

4. Position the bearing support plate (9) on the structure.

5. With the isolator phases in the closed position, fit the inter-phase coupling rods (11) between the centre phase centre pivot assembly (12) and the outer phases turntable levers (4). Adjust their length to ensure simultaneous opening and closing of all 3 phases.

6. Fit the vertical coupling pipe (2) in position through the bearing.

7. Fit the coupling assembly and drive rod (10) between the coupling pipe crank and centre phase lever.

8. With the phase contacts closed and the hand operating mechanism (1) in the CLOSED position, couple the vertical coupling pipe (2) to the hand operating mechanism (1) by means of the M10 set screw and lock in position.

9. Operate the switch and check that the contacts are fully closed with the handle in the fully CLOSED position. If necessary, adjust by slackening the u-bolts on the drive rod (10), adjust length and re-tighten the u-bolts.

10. Open and close isolator a number of times to ensure smooth and correct operation.

11.After the conductors have been secured to the terminal pads, check contact alignment.

12.All contacts will have been cleaned and greased before despatch. Only if necessary, clean contact surfaces and apply recommended contact paste.

13. Check any secondary wiring, terminals and fixing screws for tightness.

14. Note spaces, item 13 to mount items 1 and 9 to the structure as supplied as standard 76 x 38 channel.

Maintenance

These isolators require very little maintenance. However, it is recommended, dependant upon the environmental conditions, to attend to the following, once in 3 to 5 years.

1. Grease all bearing points via nipples provided.

2. Clean main contacts with transformer oil and recoat with recommended contact paste.

3. Operate isolator several times to check smooth operation and operation of auxiliary contacts. Only re-adjust settings if found to be necessary.

Adobe PDF

Download this page in PDF

 

————————— MCWADE INTER-CONNECTOR CLAMPS ————————————————-
McWade Inter-Connector Clamps

TECH INFO: MCWADE INTER-CONNECTOR CLAMPS

 
Installation Procedure

All inter-connector clamps as manufactured by McWade Electrical are designed to suit both the electrical transfer current carrying capacity of the stranded/tubular busbar it is to be utilised with and the mechanical strengths associated with the rated short circuit current.

All international manufacturers’ inter-connector clamps can only perform to their designed electrical and mechanical functions subject to the correct on-site installation procedures being adhered to which are:

1. Clamp Selection
The first step is to ensure that the clamp to be utilized is suited to the application in question. McWade clamps are all stamped with both Type Number and Conductor sizes and these can be compared to those specified on the installation drawings. It should be noted that types KC and YC are to be used solely for the compression connection of conductors to equipment terminals. The only time a bolted connection is made to stranded Conductors is in the case of TEE joints or tap-off where the clamp types T, TC or K are utilised.

2. Cleaning Procedure
All clamps are supplied ex-factory in heavy duty heat-sealed plastic bags and the clamps should only be removed from these plastic bags immediately prior to installation and after correct cleaning and preparation of the installation connection area.

Aluminium alloys as utilised in stranded or tubular conductors are prone to immediate oxidisation after extrusion. This oxide layer can achieve a maximum thickness of 500 – 1000nm and acts as an insulating medium. The dynamics of an oxidised aluminium connection results in a very high resistance interface and causes thermal instability leading to connection failure. To ensure proper contact between the busbar and clamping contact areas, it is necessary to clean away the layer of aluminium oxide in the contact areas.

Preparation of Contact Surfaces
All contact surface areas must be strongly brushed with a steel-wire brush alternatively with an aluminium oxide emery cloth grade 80 – 180 and then wiped clean with a dry cloth. Immediately thereafter the contact surfaces of the stranded/tubular busbar and inter-connector clamp are to be greased with a high-melting point non-oxidant grease to a 0.25 – 0.5mm minimum thickness. This greasing process must be immediately followed up with the application of the inter-connector clamp to the respective busbars.

Care should be taken that the contact surfaces, which have been cleaned and greased, are kept free of sand and other foreign matter. In the case of accidental pollution these surfaces shall be cleaned with a suitable solvent and the cleaning and greasing process repeated.

Equipment terminal studs and palms whether of aluminium or plated copper are to be cleaned in accordance with the above procedure.

Certain compression compounds contain an aluminium grit and upon compression of the conductor sleeve an conductor, the compressive force drives the grease, containing sharp metalgrit particles, between the conductor strands, at the same time forcing the conductor strands into a semi hexagonal shape, this effect breaking down the oxide film around the inner conductor strands and providing for a point-point contact.

3. Clamp Installation
When installing the inter-connector clamp, ensure that the conductor seating areas match those of the busbar that the clamp is to be fitted to. In cases where the aluminium tubular busbar is slightly beyond the tolerances for diameter and ovality, the clamp can be accurately bedded onto the tube by hammering around the outside of the clamp body shell with a rubber hammer. This can only be done whilst the clamp is clamped onto the tubular basbar and the bolts are to be re-set afterwards with a torque wrench.

4. Clamping Sequence
Once the caps are correctly positioned, final bolt tightening is to take place according to defined sequences in order to apportion correct stresses to the conductor/tubes as well as the inter-connector bodies.

5. Positioning of the Caps
It is imperative that the clamping covers are tightened down in a parallel sequence so that the gap between the clamp’s body and the clamp’s cover is equal on both sides.

6. Bolt Tightening Torques
All clamps are fitted with bolts, nuts and washers of either:

  • 8.8 grade high tensile steel bolts (HDG and/or MoS² galvanised)
  • Stainless steel grade A2/A4
  • Aluminium alloy grade 7075 – P60

All inter-connector clamps are designed to provide a maximum effective contact surface between the busbar and the inter-connector clamp for the efficient transfer of electrical current. This maximisation of effective contact surfaces can only be achieved by the correct contact pressures of >6N/mm² being applied to the clamp. This can only be achieved by all bolts being tightened with a torque wrench to the required torque as stated below:

Tech_Misc_mcwade_interconnector_clamps_ti_1
1. Compression Joints

The conductor size to be compressed must correspond to the conductor diameter stamped on the compression tube. The conductor is to be cleaned as stated above and then cut to the required length. It is inserted into the pre-greased compression tube until the end is firmly against the clamping body stop. Compression is to be undertaken using a suitable 30/45-ton rating power operated compression tool. Compression dies are to be checked to meet with the following sizes:

Tech_Misc_mcwade_interconnector_clamps_ti_2
Dies reference numbers are to be checked to the number stamped on the compression tube. Compression of the tube and conductor should commence from the conductor end towards the clamp body and compression must be effected over the compression marks detailed on the tube.

Compression tools are to automatically bypass on complete compression and under no circumstances should the die pressure be released before bypass is reached. After full compression the die numbers 42 or 58 will be imprinted onto the tube and serve to indicate both satisfactory and complete compression.

Compression tools are to be treated strictly in accordance with the operating instructions supplied. A light film of pure white Vaseline should be applied to the compression die faces after every 5 – 10 compressions in order to extend die life and facilitate die slide over the compression tube surface. Any compression die flashes should be removed with a file.

Upon completion of the clamp installation and checking that all bolts are correctly torqued surplus grease should be wiped away.

1. Installation of Expansion Tubular Busbar Inter-connector
When installing full or half expansion inter-connector clamps care must be taken for the allowance of the thermal expansion of the relevant basbar tube, be it aluminium or copper. An estimate of the expansion of various tubes due to thermal expansion at various temperature changes is given in the table below.

Tech_Misc_mcwade_interconnector_clamps_ti_3
Example of the Calculation of Thermal Busbar Expansion

Aluminium basbar tube, length =10m

Temperature differencet=Max. Op. Temperature – Min. Op. Temperature
=(+80°C) – (-20°C)
t=100°C
Assembly temperature=+20°C

For complete expansion length refer to table – 24.0mm.

Temperature difference between the final temperature (+80°C) and the assembly temperature (+20°C) is therefore 60°C. Referring to the above table, the corresponding expansion difference will be 14,4mm. The clamp must therefore be mounted in such a way that a shift of at least 14,4mm in the direction of the clamp centre is guaranteed. A shift in the opposite direction in accordance with the temperature difference of (+20°C) assembly temperature and (+20°C) being the lowest final temperature – 40°C. Referring to the above tables, this value is given as 9.6mm.

2. Tube Operations

Aluminium tubular busbars are subject to wind-generated vibration and oscillation. Because of the low self-damping of tubular busbars very slight excitation forces will suffice to excite the tubes to vibrations amplitudes of the order of the tube diameter, when there is a resilience of the excitation force with a natural frequency of the tube. These high amplitudes produce additional dynamic stresses inside all structural parts and it is often necessary to dampen this tube oscillation by the insertion of AAC conductor into the busbar. The increased self damping provided by the insertion of damping conductor delays the onset of resilience build-up and this limits the maximum amplitudes created by a given excitation force.

Tech_Misc_mcwade_interconnector_clamps_ti_4

Adobe PDF

Download this page in PDF

 

————————— OPERATING ‘BIMETAL 4E’ HYDRAULIC TOOL ——————————————
Operating 'Bimetal 4E' Hydraulic Tool

TECH INFO: OPERATING ‘BIMETAL 4E’ HYDRAULIC TOOL

1) Remove tool from case checking there is no oil leaking in the case (if oil is present check pressure with gauge).

2) Hold unit in both hands, and pump handle 9 times, at this stage all 4 nibs should be touching each other, release pressure by rotating pump handle anti clockwise and closing handles together, this action will engage the release mechanism at the base of the handle and the 4 nibs will open. “Repeat twice”

3) Now we are ready to exert high pressure on the tool with all the operating parts and “O rings” lubricated.

4) Pump unit to close nibs (9 pumps) pressure will automatically change over to high pressure with a high pitched sound, now 2½-3 pumps should enact by-pass valve and the pressure will fall away, should the tool not reach by-pass stage, do not crimp any fittings as they will be under crimped. If in fact the tool takes 4-6 pumps to by-pass it will over crimp.

5) All tools should be checked by an appointed representative (i.e. safety office) every six months for oil leakages and general tightening up (Screws etc.) All tools must be serviced every 12 months. (Oil changed and pressure set) by the supplier.

6) Danger: Do not engage in repairs and services without first-hand knowledge of hydraulic tools as this could lead to a very expensive repair at a later stage.

7) Placing the fitting in the tool pump handles until the fittings is firmly held in place, making sure that the fitting is held by all 4 nibs and that the fitting has not slipped between two nibs.

8) On all joints, crimp from the outside towards the middle-stop, making sure you do not crimp that extreme ends.

Tech_Misc_operating_bimetal_4e_ti_bt1
9) Remove cap and insert or apply fitting to conductor (after cleaning and straightening) now pump handles until tool by-passes, you will first feel resistance to your pressure applied and at by-pass, no resistance to you pumping the handles together. Move tool to next set of marks and repeat operation, until all demarcations have been crimped.

10) If you have not straightened your conductor before you crimp it, and it does banana, do not try to straighten it by hitting it with a hammer, or the like, leave it alone. You will only do more harm than good.

11) Always make sure that the opening of the fitting throat faces out of the crimping head towards the line so that the line can enter straight in.

Tech_Misc_operating_bimetal_4e_ti_bt2
All OPEN THROAT connectors are located in the tool head as shown in the adjacent illustration. The tool nibs are advanced to lightly grip the connector profile at the position where the first crimp is to be made. Subsequent compressions are made by sliding the tool head along the connector.

12) The “Bimetal 4 E” Hydraulic tool has been designed exclusively for overhead line fittings, to let it help you take a rest when up the ladder. Hang the tool on the conductor over the fitting when resting.

13) After completing crimping your compression fitting onto the line “Do not drop” the tool onto the ground, but let it down slowly or carry it down the step ladder.

14) Always replace the crimping tool in the steel carry case after use.

Training courses for the correct operation of the tools as well as installation procedure of Crimp Fittings can be arranged either on site or at our offices. Please liaise with your sales representative to schedule this training.

Adobe PDF

Download this page in PDF

 

————————— RUN AND TAP CONFIGURATION ——————————————————
Run and Tap Configuration

TECH INFO: RUN AND TAP CONFIGURATION

International understanding is that the RUN conductor (immaterial whether stranded or tubular conductors) is always in the horizontal plane and that the TP conductor (whether stranded or tubular conductor) is in the vertical plane

The K type cross clamp is specifically designed for use with a SOLID EQUIPMENT STUD and STRANDED CONDUCTORS. The K clamp is manufactured in compliance with the Eskom NWS 1671 specification, which specification calls for one half of the clamp having both the horizontal and vertical cross grooves smooth bored to suit 26 or 38mm dia equipment studs – with the other half of the clamp having the horizontal and vertical cross grooves either machined or cast serrated to suit stranded conductors of 16.3, 19.0, 21.0, 26.5 and 38.5mmdia. These are the standard Eskom stud and conductor diameters and the BME manufactured K clamps are manufactured to suit these stud and conductor sizes where in all instances the stud is normally classified as the tap side of the clamp, immaterial of whether the stud is vertically or horizontally mounted.

Where a standard K clamp is required to be used with either different conductor or stud sizes, the standard K clamp as manufactured by BME requires to be modified to suit these different stud/conductor sizes. This modification requires moulding pattern alterations and machining of both clamp base and covers to suit the required sizes. This machining operation is an added cost and in order to reduce these costs which require a modification to both the vertical and horizontal seating grooves on both halves of the K clamp, it is required that customers specify both the RUN size and the TAP size in each specific case, thus the machining modification will only be carried out on one groove of each half section of the clamp. Should the clamp require both the H and V cross grooves on both halves to be machined, this will be undertaken, but at an increased cost.

Adobe PDF

Download this page in PDF

 

————————— SUBSTATION CLAMPS: GENERAL FEATURES ——————————————–
Substation Clamps: General Features

TECH INFO: SUBSTATION CLAMPS: GENERAL FEATURES

INTRODUCTION – CURRENT CARRYING CLAMPS FOR USE IN ELECTRICAL SUB-STATIONS

1. McWade Productions (Pty) Ltd manufactures and markets a comprehensive range of both aluminium and copper alloy clamps for use in all electrical conductor and/or tubular busbar applications. This range varies from small conductor termination clamps used at less than 500 volts up to large diameter tubular busbar clamps suitable for use on 250mm diameter busbars at 765kV and rated in excess of 6 500 amps. The clamps are manufactured to the company’s own designs and/or to meet specific customer requirements.

2. When designing substations and, particularly when determining the type of current carrying clamp to be utilised, the maximum continuous load rating and short circuit currents are critical factors to take into account. This is particularly important with the high load factors now occurring in some power systems. Internationally, substation design now tends towards the use of tubular bus systems as opposed to overhead strung conductor type busbars where with current ratings in excess of 3 000 amps, strung busbars require more than 3 conductors per bus phase with the resultant complications arising in the connection of these bundle conductors.

Bundle conductor bus systems are subject to bundle collapse under short circuit conditions which generate serious shock forces at attachment points. At voltages in excess of 88/132kV tubular bus arrangements lend themselves more towards a superior corona free design than do bundle conductor bus systems. Furthermore, the use of tubular bus systems provides for a lower profile and more aesthetically acceptable substation design. When utilising tubular busbars, short circuit forces between phases with relative small phase spacings, do present a problem and these forces must be allowed for in the mechanical strength in the clamps and the post insulators used.

3. The clamps, as detailed in this catalogue, are manufactured to comply with the requirements of the National Electrical Utility of South Africa being Eskom as well as international specifications.

a) Aluminium Clamps

Aluminium alloy clamps are predominantly used for the connection of stranded aluminium conductors and/or tubular aluminium busbars to each other and to hot dip tinned copper equipment studs and terminals. Where corrosion is a prime factor, and the terminals not tinned, bi-metallic washers and/or sleeves should be fitted to the copper terminals. All aluminium alloy clamps are supplied pre-greased if required.

b) Copper Clamps

Copper alloy clamps, which are hot dip tinned, are predominantly used in copper to copper applications. Where corrosion is a factor to be considered, they are also used in copper to aluminium applications. Copper clamps are supplied un-greased.

TECHNICAL

CORROSION OF INTER-CONNECTOR CLAMPS

Two factors are associated with corrosion:

1. Atmospheric action
2. Galvanic action

For atmospheric action to result in corrosion there must be moisture and oxygen present.

Galvanic action results in corrosion when two dissimilar metals in the electrolytic series e.g. aluminium and copper are in physical contact. In this case moisture acts as an electrolyte.

In such an instance the copper becomes the cathode and receives a positive charge. The aluminium becomes the anode and receives a negative charge.

The resultant current flow attacks the aluminium leaving the copper unharmed.

Both factors described above are influenced by environmental conditions.

This occurs in rural areas to a lesser extent than in urban centres and more so in heavy industry locations – steelworks, chemical plants, refineries etc.

The problem of the mechanical jointing of two dissimilar metals in physical contact with each other, such as aluminium and copper stems from their difference in electrolytic potential.

The extent, or severity, of the corrosive action is proportional to distance or separation of the metals in the list i.e. the magnitude of the difference in electrolytic potential of the two metals which, in the case of aluminium and copper is quite considerable.

Aluminium to Aluminium Connections

No problem exists in the jointing of these conductors as electrolytic action is non existent. Nevertheless, care must be taken to prevent crevice corrosion and to select an aluminium alloy connector body not liable to stress corrosion cracking.

Aluminium to Copper Conductor Connections

The best choice is an aluminium bodied connector since it is not subject to the galvanic attack of the more vulnerable element – the aluminium conductor.

Nevertheless, it is good practice to use an inhibitor grease, on the aluminium connector body or on the aluminium conductors and additionally where-ever possible to install the aluminium conductor above the copper to prevent pitting from the galvanic action of copper salts washing over the aluminium connector and conductor when in a lower position, alternatively a hot tin dipped copper alloy connector is to be utilised or an aluminium connector with a bi-metallic sleeve placed over the copper conductor.

Electrical Jointing of Aluminium

A particular phenomenon associated with jointing of aluminium conductors concerns the oxide film that forms rapidly on the surface of freshly extruded or cleaned aluminium exposed to air.

This oxide film acts as an insulating medium and must be removed with a scratch steel brush or abrasive paper in order to achieve a satisfactory and reliable electrical joint.

This problem with aluminium is that the freshly cleaned surface is liable to fast oxide formation, hence it is important to coat the surface with an oxide inhibitor immediately after cleaning.

The function of a contact/compression compound is:

a) Firstly to act as an oxide inhibitor by preventing the ingress of moisture and air and to provide for continuing protection against further corrosion of the electrical joint in its working environment.

b) Secondly, with certain compression greases under compressive force, its high content of sharp metallic particles penetrates through any remaining oxide film to provide multi contact current carrying bridges.

Inter-strand resistance

The high contact resistance due to aluminium oxide on the strands of aluminium conductors may be responsible for the poor distribution of current throughout the conductor strands. Thus some strands may carry much more than their share of the current, with consequent overheating of the conductor.

The most effective way to overcome inter-strand resistance in aluminium conductors is by the use of compression connectors filled with a compression-jointing compound.

Note: While oxide films on copper are conducting mediums, and more easily broken by contact pressure, it is a recommended practice to clean badly tarnished old copper surfaces with a scratch brush.

Adobe PDF

Download this page in PDF

 

————————— TUBULAR BUSBAR CLAMPS IN ALUMINIUM ALLOY —————————————
Tubular Busbar Clamps in Aluminium Alloy

TECH INFO: TUBULAR BUSBAR CLAMPS IN ALUMINIUM ALLOY

The aluminium alloy tubular-bus current-carrying clamps depicted are manufactured in certified aluminium alloys, namely aluminium alloy grade LM-6 (HS) as a standard, alternatively in aluminium alloy LM-25 heat treated to a T6 temper where a stronger clamp is required to comply with a higher strength rating. Standard South African busbar tubes are supplied in either the alloys D50S and/or B65S, which are both suitable for electrical purposes. The D65S alloy has better mechanical properties, but somewhat poorer electrical properties than the D50S. However, for application in HV yard, where long spans are essential, the D65S alloy with superior mechanical properties is preferred.

Tech_Misc_tubular_busbar_clamps_alumin_alloy_ti_tbcaa1
Proposed current ratings for various tube sizes, having wall thicknesses of 4,6 and 8mm respectively, are given in the table below.

Nominal Outdoor Current Ratings for D65S Alloy Tubes

Tech_Misc_tubular_busbar_clamps_alumin_alloy_ti_tbcaa2

I = Moment of Inertia Z = Modules of Rupture

*Ratings apply to an average height above sea level of 2 000m maximum busbar temperature of 85°C and ambient air temperature of 35°C.

Tubing – length available ex-mill – SA

Tech_Misc_tubular_busbar_clamps_alumin_alloy_ti_tbcaa3

Adobe PDF

Download this page in PDF

 

 

McWade Productions

Based in Gauteng, South Africa, McWade Productions is a leading supplier of electrical components and accessory equipment to the African and international Transmission and Distribution Electrical Industry.

Call us on +27 11 316 2262

We would be pleased to have a conversation with you about our company and its services
 
Contact Us

Search this Website

Type in your search terms & press the 'Enter' key
© All Rights Reserved   ·   Copyright and Warranty Notices   ·   Website by Cool Design